【 Weak current College 】 data center equipment monitoring system form and application---Power By 【 China power house network 】
As computer technology development and diffusion, the increasing number of computer systems, and its accompanying environmental equipment also day by day increases, the data center has become an important part of the unit. Data center room environment equipment (power supply, UPS, air conditioning, fire protection, security, and so on) must provide for the computer system at normal operation. Once the engine room environment equipment fails, it will affect your computer system's operation, data transmission, storage and system's reliability, such as accident and could not be processed in a timely manner, it could damage the hardware equipment, and result in serious consequences. For State bodies, banks, securities, customs, post office, etc need real-time Exchange data units of the engine room, room management is more important, in the event of system failure, the consequent economic loss is immeasurable. Therefore the engine room must be intelligent monitoring and management, unified control room equipment. This can reduce the room maintenance staff burden, facilitate centralized management of equipment, improve system reliability and availability, lower management costs and improve efficiency.
1 computer room environment monitoring system form
All the rooms and the environment of equipment for centralized monitoring and management, computer room project recommended computer room environment monitoring system, the monitoring objects as individual subsystems constituting room, including dynamic systems, environmental systems, fire systems, security systems, network systems, as shown in Figure 1. Computer room environment monitoring system based on network cabling system uses a distributed monitoring and control, in the engine room monitoring room placement monitoring host, run the monitoring software to a unified interface for centralized monitoring of all sub-system. Real-time monitoring of all system devices running and working parameters, find parts failure or argument exception, instant take multimedia animation, voice, telephone, SMS, alarm mode, recording historical data and alarm events, provide intelligent expert diagnosis and remote monitoring and management features to Web browsing.
1.1 dynamic environmental monitoring system
Dynamic system monitoring including room all power equipment, such as high-voltage power distribution, low-voltage distribution, diesel generator, power distribution Cabinet, UPS and DC power supply system lightning protection system, battery, etc.
(1) power supply: monitoring level, secondary Exchange distribution Cabinet of main circuit and all the various parameters of a return. Such as voltage, current, frequency, power factor, active power, reactive power and apparent power, etc.; monitoring levels switch on or off. Displays and records the various parameters of the change curve, and a variety of alarm State records and alarm processing.
(2) diesel generator: monitoring the generator output voltage, current, frequency (speed) and water temperature, oil level, oil pressure, and other parameters; the operational status of the generators, fuel valve switching State and other States of real-time recording and alarm handling; control generator start and stop.
(3) UPS: UPS vendor UPS communication protocol, you can monitor the agreement of all the parameters and status. Parameters including input and output voltage, current, frequency, power, voltage, battery backup time, temperature, etc.; States including rectifier, inverter, battery, the bypass, the load and other parts of the State; displays and records the various parameters of the change curve, and a variety of alarm State records and alarm processing.
(4) DC power supply system: monitoring the State of input power, battery voltage and status, display and record the battery voltage, battery temperature curve, and on the various alarm status in real time recording and alarm processing.
(5) lightning protection system: monitoring power supply SPD working state, on the SPD was struck by lightning or surge damage for real-time recording and alarm notifications.
1.2 air-conditioning equipment monitoring
The engine adopts precision air-conditioner, the user may act according to the precision air conditioning supplier communication protocols, real-time monitoring of precision air conditioning of air temperature, humidity, cooling water temperature and flow in and out and refrigeration, cooling water pumps operating current parameters; monitoring status including compressor status, fan status, heater, dehumidification device status (water-cooled air-conditioning can also be monitored to the cooling towers of the pond surface State, cooling tower fan status, cooling water valve status, etc.) and other working conditions; displays and records the various parameters of the curve, and a variety of alarm status in real time recording and alarm processing. Control air conditioning in the start-up and shut-down, adjust the temperature and humidity.
1.3 fire system monitoring
Through the acquisition of fire or smoke detectors, controller of temperature detector of alarm signal real-time monitoring of the fire and police state, when the fire monitoring system with intuitive screen displays the alarm message and alarm notifications, control measures such as the door opened the wind equipment, start-up and other related equipment.
1.4 temperature and humidity monitoring
Through the acquisition of temperature and humidity sensor monitoring of temperature and humidity data, to intuitive screen real-time recording and display room of regional changes in temperature and humidity data and curve, as well as transboundary alarm information processing.
1.5 video surveillance system
Video monitoring system uses the concept of the video configuration, each channel of the image to control the configuration of a random insertion interface, for a large monitoring system, the electronic map way to centrally manage all site data and images of the interface that is very convenient. Due to the dynamic environment monitoring and closed circuit monitoring into one, and therefore can achieve dynamic environment and image of linkage control, once an exception occurs, the control system automatically eject the scene image screen, instant video and repeat alarm and processing.
1.6 leakage monitoring system
For the computer room, water cannot be ignored security one of the main content. Modern rooms housed many precision electronic devices, such as switching, network servers, and provide constant temperature and humidity environment by private air conditioning, and air conditioning operation requires to have the humidification of the water and drainWater and air conditioning of condensed water. Air conditioning of water system on the floor following numerous transmission cable and the power plug and terminal box constitute great harm, even if it is a very small leaks, can also cause computer room equipment operation breakdown, incalculable economic losses. In order to guarantee the room network equipment uptime, installed in the floor of the leakage protection on computer room equipment is very important. The precise location of the leak was found in a timely manner, in a timely manner, to ensure the security of the entire system.
Water leakage monitoring system leak through the acquisition of alarm signal monitoring host any leakage of water leakage sensors, in the event of an alarm, immediately cut off on the water pipes and water mains water solenoid valve on the completely closed water, cut continue to discharge occurs, and you can locate specific leak detection system, at the same time, the alarm message via SMS platform is sent to the relevant managerial personnel, and on site audio and light alarm.
1.7 intelligent access control system
By access controller, an access card, card reader, electronic locks, Network Extender, access control management software, management, computer, etc., to enable the engine room access control, access information, login, security alarm, alarm, while providing a variety of forms (RS485, wireless modem, dial-up, TCP/IP, SMS, SP) networking features.
2 room equipment monitoring system role and significance of
(1) implementation of few people or unattended, centralized maintenance, centralized management
Use of computer room equipment monitoring system's basic aim is to make the room equipment, real-time automatic monitoring for few people or unattended, change the past of backward maintenance mode. Accurate, fast and true data full performance equipment and systems of health, is a centralized maintenance and guarantee of centralized management. As a result of the advanced design and construction, can do not increase the maintenance personnel. Practice shows, the engine room equipment monitoring system to achieve the reduction in duty personnel, improve maintenance levels, improve work efficiency.
(2) provide for the maintenance of the real technical data, promoting scientific maintenance management
Building room equipment monitoring system's ultimate aim is at least one or unattended to achieve scientific and new maintenance management mode of operation. A large number of real-time data, intuitive reflect the equipment, systems of real state. Through the monitoring data of scientific processing, analysis, qualitative or quantitative work on equipment and systems for accurate evaluation of quality. Can to a large number of technical data, maintenance and repair of guiding device, using expert system, made of equipment maintenance plans. Make full use of equipment automation, use scientific operating procedures put the past behind and complex monitoring methods and methods for improving refining, and through advanced automatic monitoring tools, and equipment maintenance work in simple, easy, accurate and efficient. If the generator from the start with a load test and DC systems, UPS battery capacity check-checks the ingenious combination of unified centralized monitoring arrangements, can simultaneously access a wide variety of equipment of surveillance data. In the expert system of support, accurate analysis of the results, thus guiding device fault prevention and repair and replacement.
3 room equipment monitoring system application results and prospects
Room equipment monitoring system can quickly and accurately complete the data collection and forwarding so that maintenance personnel can immediately see the health of the machine room, you can also display the room of concentrated and provided on-site monitoring picture, unusual, automatic alarm, ensure the stable operation of the engine room equipment; improving the security of the computer room management performance and reliability of the engine room of scientific management.
From the fields of application, the engine room monitoring will be increasingly widely used. The engine room monitoring system in all industry areas on which there is an urgent need. For example, a supermarket chain, in large factories, key government departments, business sector, financial institutions are required to adopt decentralized deployment and centralized monitoring system complete 24/7, unattended monitors work for their business security, escort high-efficiency work.