Wednesday, January 26, 2011
【 Weak current College 】 warm IX errors
First, the water warm moist, electric heating and drying?
Water floor heating of water is heated by the carrier, is not the role of regulation room humidity. Warm and comfortable or not dry because of the low-temperature radiant floor heating is heating the envelope's heating, low temperature and radiation both determines how high his comfort. If the estimated indoor moist so that everyone would have a headache, that means that the heating system may leak.
2. home installed air conditioning and floor heating is installed, is not a duplicate investment?
Of course not repeated investment. Air conditioning is the biggest refrigeration, heating function is his Deputy if air conditioning heating in winter is not only a waste of resources, and costs will be high. But the floor heating is a professional, not only saving zhinuan, are not very expensive, therefore, whether from economic accounts, or heating comfort, a warm air conditioning also do, is not wasted, not to be repeated investment.
3. control of water temperature low temperature water supply can be implemented
All responsible European boiler manufacturers do not recommend or oppose, directly to boiler water temperature down to meet the warm temperature water (no more than 60 ° c) the risk is likely flue gas condensation water and seriously damage the boiler service life, Germany heating system most used fixed water temperature constant mixing equipment on a second regulation, there is another way is based on the climate temperature on water temperature compensation adjustment, which can further conserve energy, reduce costs.
4. heating heating rate the sooner the better
Floor-heating radiant heat determines how its reach housing heat balance will be a long process, generally the initial need 6-7h time, and for system debugging may need longer, according to Germany to warm the standard, does not allow to shorten the time and improve the water temperature, whichmay cause cracking of cement and floor tiles
5. the surface temperature is higher, the better
In Europe, the low-temperature floor heating both for saving energy, but also for health requirements in Germany to warm after 30 years of development, and related medical research also indicates that the surface temperature does not exceed 28 ° c, could reach 30 degrees centigrade, local, and if the ground surface temperature over the safe temperature, it can cause vascular dilatation of the body and cause a variety of diseases.
6. heating is very simple and does not need to design
Many customers that heating is very simple, only need ground covered tube can, in fact, this is the biggest mistake. Warm as HVAC professional is a new technology, design than traditional radiator system more complicated, because the design is the foundation of good construction, design reasonable or not directly related to and affect its performance, the ground cracked, and a series of issues that also affect other work smoothly and quality level. Floor heating system design should be rigorous serious computing and meticulous study. No professional floor heating design, that is, using the best heating products, high quality construction of heating of floor heating system is poor.
7. as long as the plumber one that can pavement heating
Many owners to lower initial investment, find a heating company designers do about design and decoration companies in accordance with the design drawings for plumber one that warm the construction, in fact, this is your irresponsible behavior, warm like heating just simple disassembly and Assembly, he needed to warm the construction personnel according to drawings for professional construction of floor heating. When heating to warm the pavement coil bending radians is too large, too small will affect the heating effect of the use, of a non-professional construction of heating construction personnel, warm paving results maywant to instead of, although there is a professional design, but no professional heating construction, it is a good product is also a pile of scrap metal, warm quality also cannot guarantee.
8. all you can do to warm houses
Due to the heating with energy-saving and comfortable features that many owners renovated House wanted to be warm, but not all of the House are suitable for floor heating, floor heating on the distribution of the pressure differential is has its own unique requirements, usually heat sink on the system requirements of the smaller, but warm on pressure requirements are relatively large, if without modification, it is easy to cause another user heating not hot. If you have problems with the pipeline pressure of residential heating, floor heating pipes made by pressure burst, so not only their own losses, but also compensation for the loss of the neighbor's House, in which case the loss is incalculable. So choose warm to the housing of the heating system of the nature of the choices.
Nine more dense, floor heating pipe, the better
In floor heating design time many owners are admitted to warm the coil, the more dense the better, the more the more dense, warm room, floor heating coil spacing of design is based on various factors in accordance with the relevant data with formulas make calculated, coil spacing is too tight, not only because of the indoor temperature is too high, causing dry heat can also affect human health.
High-quality heating system is a professional floor heating design, high-quality heating products, specifications of floor heating construction to complete, each link is to ensure quality. So when you choose warm from multiple angles, do not blindly choose. Only the right choice, go out to warm the misunderstanding, can guarantee the quality of floor heating.
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments: