Saturday, January 29, 2011
College】 【weak power of the emergency elevator --- Power By 【China】 weak home network.
<br> either power failure or malfunction caused by accident elevator stopped their ladders, fire protection system or because a fire is reported to the elevator landing, gave great inconvenience caused by ladder personnel and even the frightened passengers. .To this end, the following procedures should be strictly implemented to ensure the safety of passengers. .1, when the fire control system to report a fire caused when the elevator stopped, fire staff on duty should be calm and quickly identify the location and number of alarm points, telephone notification of security personnel on duty Jifu Live View, but with the intercom to remind passengers to remain calm. .When the scene confirmed that the fire must immediately notify the management office of personnel fire fighting and rescue and stop the lift operation. .If the system false alarm, as soon as possible to troubleshoot and restore the normal operation of the elevator. .2, the sudden power outage caused by the elevator or escalator to stop running their own fault, fire duty officer through the intercom to tell passengers should not panic, not any part of the body outside the car stuck, and then immediately notify the Engineering Department staff, under the floor lamp .direction or open the outer door look carefully to determine the location of the car, leave the car trapped in the rescue, before the lift off the power failure, as the case according to the following steps to release the trapped passengers. .(1) car parked near the location of the entrance hall staircase waiting, and the higher or lower than the floor no more than 0.5 meters, with a special key to open the outside door outside door, while the slow force open the car door, help passengers to safely leave .car, then the outer door shut. .(2) car parked away from the location of the entrance hall staircase Hou, if the car door in a semi-closed state, should be completely closed or open it first, and then by manually turning the car close to flat layers, the outer door with a special .key to open the car door to rescue the trapped people, then the outer door shut. .(3) manual drive car, for at least two and one hold on disc wheels, the other forced open the brake, release the brake every time, turning once, for intermittent operation. .If the car stopped on the top or bottom of pending staircase position above or below the door, should release the brake disc at the same time hold the wheel tight, turning the car with a human in the right direction, so after the car is strictly prohibited Brake .self-moving car. .(4) If the elevator stop for safety gear, manual drive vehicle can not force the window to rescue the stranded from the safety of passengers. .3, lift their own failure to rescue the trapped immediately after the overhaul of personnel, to identify causes of accidents and eliminate hidden dangers, if not self-study, must be notified as soon as the elevator maintenance professionals to troubleshoot and restore the normal operation of the elevator, and write an accident .Management Office submitted a written report to General Management..
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment