Wednesday, January 26, 2011
Weak current College】 【elevator operation management.
<br> <br> Elevator equipment operation management, is the guarantee of the good operation of the elevator of management activities. The main contents include: elevator equipment run inspection monitoring management, Elevator exception occurred in the management, management of elevator machine room and .elevator files management, etc. <br> First, the operation of the lift equipment inspection monitoring management <br> Visit monitoring management, by elevator watchkeeping, scheduled on elevator equipment inspections, inspection and found the problem in a timely manner. Elevator watchkeeping daily .on the elevator for a visit, according to the inspection of fill out the "elevator equipment inspection records as table 4-7-1. <br> <br> (1) the establishment of inspection monitoring management system <br> Company engineering Dept .of elevator administrator, according to the elevator performance and operation of developed elevator inspection management system. And supervision to perform watchkeeping. <br> <br> ① on duty daily on the main part of the elevator inspected once. <br> <br> .② visits on request inspection of contents carefully. <br> <br> ③ timely processing of visiting your problem and do the inspection record <br> <br> (2) inspection of contents <br> Watchkeeping inspections should note: traction machine if .there is noise and smell, is hot; bearing bolt is loose; gear box oil, the oil color is normal, the axle for solid and reliable; indicating instrument, LEDs, each relay has normal; transformer, reactor, and so is overheating; .actuator is normal; traction wheels, Dray, speed limiter, etc. is normal; telecommunications facilities, badges, spare wheel and driver and rescue tool will wrench is placed in the specified location; there is no vibration elevator, switch door is smooth; pit .speed limiter is normal. <br> <br> (3) the negative situation found in inspection processing <br> When the inspection found a bad state, watchkeeping shall promptly take measures to adjust. If the problem you should promptly report company engineering Dept .head, in collaboration with the competent for resolution. Repairs should be strictly adhered to the elevator maintenance standards. <br> <br> Second, the exception handling management <br> When the elevator exception occurred in the work of the Division of the staircase .and lift personnel are cool, keep a cool head, in order to seek a safer solution. <br> <br> (1) the disposal of fire <br> <br> ① When floor fire, Elevator watchkeeping duties should immediately try to .press the "fire off" so that the elevator into the fire in the running state. Elevator to the base station, passengers quickly leave the cabin. Telephone notification Engineering Department and dial 119 phone alarm. <br> <br> ② Wells road or .car in a fire, the driver should immediately stop the escalator and commuters leave, cut off the power after dry chemical fire extinguisher or 1211 fire extinguishers fire. At the same time, the phone informs the Engineering Department. If the fire is hard to dial .119 phone alarm, in order to guarantee the high-rise building in personnel and property security. <br> (2) elevator was flooding at the time of disposal <br> The elevator was flooding of the tunnel, Elevator stopped on the second floor .above; flooding when the floor, Elevator stopped in the water flooded in a layer, and then disconnect the power switch and immediately organization personnel, raw water shutoff is blocked after the dehumidification process, such as hot air blow dry. Using shake table test insulation .resistance, standard, you can try the ladder. On the staircase only when you can put to use. <br> <br> Third, the elevator room management <br> Elevator watchkeeping, company engineering Dept elevator administrator under the leadership of the work .. Elevator administrator is responsible for formulating the elevator room management system. Watchkeeping strictly enforce the elevator room management system. <br> <br> (1) elevator room management system <br> <br> ① non-room staff are not allowed to .enter the engine room, must be entered after the company engineering Dept Manager have agreed that in the engine room staff escorted. <br> <br> ② room should be equipped with adequate fire equipment, free on flammable and explosive substances. <br> .<br> ③ weekly clean room health, keep clean room. <br> <br> ④ to avoid unnecessary trouble, the engine room to lock at any time. <br> <br> (2) the shift system <br> < .br> ① normal shift in time. Shift workers should take over staff speak out on the day of the operation of the elevator, succession staff should review the elevator equipment inspection records, tools, etc., confirmed after running inspection record signature. <br .> <br> ② When he takes over the post staff, shift personnel shall not away. Should ask the Engineering Department elevator administrator seeking solutions. <br> <br> ③ elevator accidents, is not processed, should shift personnel continue to be responsible .for incident handling, succession staff to assist in handling. <br> <br> 4. lift the archive management <br> In order to understand the overall situation, Elevator engineering team to build high-rise buildings for the elevator profile. The archives .include: elevator lift with schematics, installation diagram, the elevator equipment inspection records, the elevator equipment maintenance records and other items. Archives of the elevator equipment inspection records, the watch head finishing a book every month, the Engineering Department elevator administrator. <br .> <br>.
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment