(A) the fire safety education and training systems
1, every year to establish fire safety knowledge propaganda posters, and other forms of knowledge competition, increasing staff awareness of fire safety.
2, regular organization employees learn fire safety legislation and regulations that govern it.
3. the Department should address status characteristics of fire safety education and training.
4, on fire facilities maintenance and use of personnel on-site presentations and training.
5, the new employees ' fire training, having passed the examination before appointment.
6, because of work needs to be carried out before the employee is reassigned to education and training.
7, eliminating control center and other special status to professional training, examinations, certificates.
(Ii) fire prevention inspections, inspection system
1, implementation of progressive fire safety responsibility and post responsibility system, implement the fire safety inspection inspection system.
2. fire-fighting work centralized management functions for the company's daily fire inspections. Monthly on the unit once a fire safety inspection and review tracking improvements.
3. check the fire hazards found in the inspectors should fill in the fire safety inspection records, and in accordance with the requirements concerned in the record signed.
4. check the sector should check the situation promptly notify client departments, the Department heads should be fire safety check daily to notify, if there is fire hazard of the unit should be timely rectification.
5. to check the fire hazards found in failing to comply with the prescribed time timely rectification of, according to the rewards and punishments.
(3) safety evacuation facilities management system
1, unit should maintain evacuation channels, safe and unimpeded evacuation channels is strictly prohibited to use, is strictly prohibited in safe export or evacuation channel effects such as installing fencing for evacuation of obstructions.
2. should the standard settings comply with the national requirements of fire safety evacuation signs and emergency lighting.
3. should maintain fire doors, fire evacuation signs, emergency lighting, mechanical exhaust air, fire, emergency broadcasting facilities in a normal state, and regularly organize inspection, testing, maintenance and upkeep.
4, is strictly prohibited in business or work during a security lock for export.
5. prohibited in business or work during the evacuation signs off, block or overwritten.
(4) fire control center management system
1. be familiar with and master the various fire facilities performance, ensure that put out the fire during operation ordered, accurately rapidly.
2. do a fire watch records and shift records, handling of fire alarm call.
3, on time-off, do watch records, equipment, incident handling, etc. of handover procedures. No shift, shift personnel be allowed to leave.
4, discovery equipment failure, should promptly report and notify the proper authorities promptly fixed.
5, non-required, shall use energy control center telephone, non-fire protection control center on duty prohibited from entering the room.
6. working time is not permitted to smoke in the energy control center, go to bed and read newspapers, and so on, should do a shift away from work.
7, discovered fire, quickly press the fire fighting plan for emergency treatment, and dial 119 phone notify fire departments and report on the Department.
(5) fire-fighting facilities and equipment maintenance management system
1. fire-fighting facilities daily use by full-time administrator is responsible for the management, full-time administrator daily check fire facilities usage, keep facilities clean, hygienic, healthy.
2. fire-fighting and fire-fighting equipment technical performance of maintenance and periodic technical inspection by the fire department responsible for centralized management of work, full-time administrator daily check in time to understand the operation of fire fighting equipment. View the running record, hear the person on duty, unusual time arrangements maintenance, the equipment shall be kept in such good order of technical state.
3, fire-fighting facilities and regular testing of fire fighting equipment:
(1) smoke, warm sense of alarm system testing efforts by the Fire Department was responsible for centralized management, and security implementation, each cigarette, temperature sensing probe measuring at least once in each of the rings.
(2) the fire pump, spray pumps, water pumps running pump per month once, check its integrity.
(3) positive pressure ventilation, smoke detection system per year.
(4), sluicing indoor hydrant, spray test once every quarter.
(5) other fire equipment test, according to different circumstances test time.
4. fire-fighting equipment management:
(1) each year in the winter, summer and during regular twice on fire extinguishers for census dressing change.
(2) regular inspections of expert management, fire-fighting equipment, the guarantee is good state.
(3) fire-fighting equipment should be regularly checked and found that the loss, damage, should complement and escalation lead.
(4) the fire-fighting equipment from the Department of management, and specify the specialist is responsible for.
(6) the fire hazard modification system
1, departments on the existence of fire hazards should be eliminated.
2, in the fire safety inspection, responding to the discovery of fire hazards are the itemized registration, and the dangers of writing issued rectification within the departments, while doing a hidden rectification records.
3, in the fire hazard is eliminated, the departments should implement measures to ensure that hidden rectification of fire safety, there is no ability to solve a major fire hazard should come up with solutions, timely manner to the unit responsible for fire safety, and the Department by the unit supervisorDoor or local government reports.
4, on fire agencies ordered corrections fire hazard shall be provided within the time limit for correction and writes out hidden rectification reply, submitted to the fire.
(7) the use of fire, electrical safety management system
1. electrical safety management:
(1) forbidden la set wires, no overload of electricity.
(2) electrical wiring, equipment installed by certified electrician.
(3) each Department, the after work off the power supply shall be shut down.
(4) the ban on private electrical bar, such as high-power electric arc furnace.
2. the use of fire safety management:
(1) strictly enforce fire approval system for securing the required fire jobs, job unit should work to fire departments for centralized management of the "fire permit".
(2) hot job before clearing the fire near the 5 m regional range of flammable and explosive hazardous materials or make appropriate security isolation, and to defend the Department to borrow the appropriate type and quantity of fire-fighting equipment at any time to spare, end job after instant return, if it has used should truthfully report.
(3) if the operation point-in-place hot construction, should be required to the job point unit manager level or more officer applications for departments need to send someone on-site supervision and inspections are not regularly send people. 2 m above the ground of elevated fire jobs must guarantee a person specializing in below may ignite any time fight other articles spark.
(4) does not go through "fire permit" without the possibility of job seekers, this unit personnel be recorded less than the second action, serious expulsion.
(8) flammable and explosive hazardous materials and place the system of fire and explosion
1, flammable and explosive hazardous materials should be dedicated to the Treasury, equipped with the necessary fire equipment facilities, employees must be made by the fire safety training of qualified staff.
2, flammable and explosive hazardous materials should be classified, stored item by item. Properties in conflict with or extinguishing methods of flammable or explosive chemicals should be kept fenku.
3. flammable and explosive hazardous materials into the library before the filing of the Inspection Department inspection, warehousing should be registered.
4. inventory items should be classified, stored, each stack pallets and covers an area of not greater than 100 square meters, stack and stack is not less than one metre between the crib and wall spacing of not less than zero point five metres, crib and beam and column spacing of not less than zero point five main channel m, a width of not less than two meters.
5, flammable and explosive hazardous materials access should be performed according to the security operation procedures, warehouse personnel should adhere to the post, non-staff not free.
6, inflammable, explosive shall be in accordance with the regulatory requirements to take fire fire-explosion protection measures and do a fire and explosion facilities maintenance work.
(9) obligations under the fire service organization management systems
1. obligations of the firemen should fire work under the leadership of centralized management business learning and fighting skills training, the technical assessment of targets to be met.
2, in conjunction with the fire-fighting facilities, equipment, equipment maintenance checks, systematically on each duty firefighters turn so that everyone has the hands-on skills.
3. in accordance with the fire and emergency evacuation plan for each half-yearly walkthrough, combined with the actual continuous improvement plan.
4. once a year the fire, fire extinguishing knowledge examination, examination outstanding given recognition.
5, continued to sum up experiences, improve fire extinguishing self-help skills.
(10) fire-fighting and emergency evacuation plan for drill system
1. to develop in line with the actual situation of the fire and emergency evacuation plan.
2, organization, full of learning and familiar with fire and emergency evacuation plan.
3. each organization should carefully planted walkthrough before deployment, a clear division of the meeting.
4, should be developed by the plan, at least every six months to conduct a walkthrough.
5. after the end of the walkthrough should convene a comment will summarize plans seriously drill, found deficiencies should be timely to revise and improve the plan.
(11) gas and electrical equipment for checking and management system
1. should the correct installation and use of electrical equipment, the personnel must be approved by the requisite training to obtain a valid certificate issued by the Department before the operation. Various types of equipment are required to have laws and regulations of the valid certificate and the maintenance department to confirm before put into service. Electrical equipment should be made by certified staff periodically (at least once a month).
2, lightning protection and antistatic equipment regularly checking, testing, quarterly check at least once, each year at least detect and record at a time.
3. electrical equipment load should be performed in strict accordance with the standards, connector firmly, good insulation, device qualified, normal and good grounding, grounding resistance shall be in strict accordance with the testing of electrical construction requirements.
4, the line should be isolated from the casing, in special cases, it should use insulated good lead skin or rubber cable. Various types of electrical equipment and wiring should be regular maintenance, always excluded due to insulation damage may be caused by a fire safety hazard.
5, without authorization, is strictly prohibited without authorization extension cord. Departments should actively cooperate with the security team, the maintenance department personnel check the extension cord is only for emergency use, shell is intact, the maintenance department personnel detection after put into use.
6, electrical equipment, switch box line nearby designated in accordance with the standard yellow area, stacked in flammable and explosive substances and periodically check and exclusions.
7, equipment used to cut off the power. Without the test of formal power equipment, installation, maintenance personnel left the scene should be cut off the power.
8. in addition to the preventive measures have been taken by the departments, workplaces do not use open fire within.BR>
9, using open fire departments should strictly observe the safety regulations and procedures, and ensure that no person with fire, the people from fire.
10, place non-smoking and smoking, posted every place employees have an obligation to remind other staff comply with the provisions of the smoking ban in public places.
(12) fire safety work evaluation and rewards
1. fire safety work performance, be communicated to praise or material reward.
2. fire safety accidents caused by those responsible, will be based on the severity of the consequences be different handling, except in accordance with State has been reached the public security Ordinance or has enough of criminal responsibility for accident liability will legally transferred to the relevant State departments, according to the provisions of this unit, be punished for the following acts:
(1) of the following situations, Visual loss and understanding manner subject to order compensation for the loss in whole or in part, be verbally warned:
A non-flammable goods, used in strict accordance with the procedures of improper conduct or custody cause fire, fire, loss not big;
B, smoking in no smoking or improper disposal of cigarette butts and cause fire, fire, loss not big;
C, failing to clean up the area of inflammable substances, the resulting fire hazard;
D, unauthorized, illegal use extension cord, power does not use security failure device or arbitrarily increase small load appliances;
E, false declaration of fire;
F, unapproved, playing with fire-fighting facilities, equipment, no adverse consequences;
G, on the Security Panel of the fire hazard is not be timely rectification and could not explain why the sector managers;
H, blocking fire channel, blocking the safety signs and so does not cause serious consequences.
(2) of the following situations, depending on the seriousness and understanding attitude, in addition to compensation for the loss in whole or in part, be informed criticism:
A, unauthorized use of flammable, explosive substances;
B, unauthorized fire facilities, equipment or to its use;
C, violation of security management and operational rules, absent resulting in fire, fire loss minor;
D, forced other employees breaches operations management staff;
E, discovery of fire, not in a timely manner in accordance with the emergency procedures;
F, on the security team check not coincide, refused rectification of the managers.
(3) any accident to hide the truth, not treatment, do not hold or provide false information, be dismissed.
(4) for violations of fire safety management lead to accidents (slight damage), but can take the initiative to frankly and actively assisting other departments dealing with incidents, recoup their losses of perpetrators or be responsible for Visual relief or exemption from punishment.