【 Weak current College 】 Otis Elevator otis3200 fault code
Fault code server display description
2000STMsoftwarereset electronic board software run error, causing CPU reset.
2001STMpoweronreset power-on reset, or press the reset button.
2002STMpowerfail5V power voltage lower than 2.5V. In the system during the outage, and system outages.
2005STMnotavailable some non-OK State was
MCSS detected, you should check the other fault logging. Furthermore, in an emergency or overhaul State also has this record
Fault source: position reference
Fault code server display description
2100PSRBigposslip and elevator operation direction consistent rope slide is too large.
2101PSRBignegslip and elevator run opposite rope slide is too large.
2102PSRPosmesfltPVT read location is located on the horizontal level area, but no input DZ, you should check the photo.
2103PSRInvFLOORCOUNT invalid floor count, floor count and the actual number of well road, floor, or exceeds the highest or lowest floor limit. Generally occurred in powered car location is the move again after a power failure.
2104PSRInvrawposPVT pulse number changes, check the exception occurred and MCSS and PVT DBSS line.
2105PSRDZerrorDZ input signal errors
2106PSRDZ1errorDZ1 input sequence error
2107PSRDZ2errorDZ2 input sequence error
2108PSR1LSerror1LS input sequence error. Elevator stopped on the ground floor, DZ action without 1LS signal or signals in 1LS 1LS switch before the action. It is also possible 1LS and simultaneous actions. 2LS
2109PSR2LSerror1, 22LS input sequence error. Elevator stopped on the ground floor, DZ action without 2LS signal or signals in 2LS 2LS switch before the action. It is also possible 1LS and simultaneous actions. 2LS
Note 1: elevator emergency stop has been executed.
Note 2: If the number exceeds the allowed number of settings and try again (installation parameters setting), the system will terminate.
Source: OCSS communication failure
Fault code server display description
2304OCSScomm.errorOCSS communication errors.
Fault source: DISS/ADISS communications
Fault code server display description
2404DCSScomm.errorDCSS communication errors.
Fault code server display description
2505DBSScomm.errorMCSS and DBSS communication timeout, or the output buffer overflow.
Source: curve generator fault
Fault code server display description
2600PGEovershoot lift across the stop position, and Acceleration, acceleration is too high.
2601PGEsynchronerr curve sync errors. once the fault has occurred, you should replace the MCSS plate.
2602PGEFXGtimeout in 4 seconds does not complete leveling action, may be the parameter GAINFIXEDPOSCT too small.
Fault sources: run logic State
Fault code server display description
2700DBSSrdy/brkDBSS status is not working properly, you should check DBSS records.
2701DBSSreadytimeout running driver status "PREPARETORUN" or reset after 5 seconds, the drive is not ready to run, the time-out failure.
2702DBSSbraketimeoutDBSS suction folded gates or release the brake a timeout.
2703DBSSdrivefault received from DBSS DBSS drive failure. You should check DBSS records.
2704DBSSstop/shutdn receives DBSS parking or downtime.
2705DBSStoquelimitDBSS beyond the torque limit values.
2706NUMBERRELEVEruns relevelling run. Too many times in the description cannot normally flat layer 1. You should check the parameter GAINFIXEDPOSCT, DELTATC, DESTINATIONLEAD; 2. You should check the photo accompanying the interposer board and cable.
2707NUMBERRECOVERruns recovery run
2708NUMBERREINITruns initialization running
2709RELEVELerr relevelling occurs when stop running, it may be a brake release slower or weighing switch is not properly adjusted.BR>
Note 1: elevator emergency stop has been executed.
Note 2: If the number exceeds the allowed number of settings and try again (installation parameters setting), the system will terminate.
Fault source: security
Fault code server display description
2800SAFabsoverspd normal, maintenance, restoration, reinitialize, learning or relevelling running the speed value exceeds the percentage of absolute speed.
2801SAFtrackingerr normal, maintenance and low-speed operation speed exceeds the actual speed and the speed of track allow directive errors caused by tracking error. Check the relevant parameters, check the PVT.
Feedback from PVT 2802SAFPVTdirerr direction and instruction is run in the opposite direction.
Only faster than 0.2 m/s for a test only. Check the PVT.
2803SAFNTSDoverspd during normal operation, the elevator in the actual 1LS/2LS speed exceeds the NTSD set value. SHUTDOWN will lift to scheduled deceleration gear stop after reset.
2804SAFCAR_NON_STRT elevator during the scheduled time (DDP) did not start due to a timeout error. In normal operation or reinitialized during run time, during the scheduled time not well road signal input. There may be a loss of traction wire rope of skidding.
2805SAFU/DinperrU/D relay input error. U/D relay feedback-contact action and instruction is run and the orientation is not consistent. Only the speed over the 0.05m/s for a test only.
2806SAFDBPinperrDBP relay input error. DBP relay feedback-contact and the required actions are not consistent, or LVC input and lock bypass expectations in an inconsistent state.
2807
SAFETSCinperrETSC relay input error.
2808SAFSCinperrSC relay input error.
2809SAFDFCinperrDFC relay input error.
2810SAFDBDinperrDBD signal input error.
2811SAFESSoperated emergency stop switch.
2812SAFSAFoperated safe loop disconnect. Or INS relay in the express runtime suddenly released.
2813SAFDFCEmergStp elevator safety circuit in DFC input point break cause emergency stop.
2814SAFFSO/ASOerrFSO/ASO relay input error.
Fault sources:
Fault code server display description
2901SAFillegalmove door without DZ signal input. Check the DZ, Panel and accompanying cables.
2903PSRlowinvspd speed-100MM/S or more disturbance may be related to the electromagnetic noise, check the Earth and shielded cable.
2904PSRhighinvspd speed occur + 100MM/S to
The disturbance may be on, and electromagnetic noise, please check the grounding and shielding of cables.
2905NUMBEROFINSPECTIONSTOP normal operation maintenance switch actions caused the sudden stop.
2906UNSAFETOSTART external lines are OK, but can't confirm safety MCSS.