Wednesday, December 15, 2010
【 Weak current College 】 North heating areas existing residential buildings heating and energy-saving alteration project check methods
<br> <br> Hebei province, Shanxi, Inner Mongolia, Liaoning, Jilin, Heilongjiang province, Shandong province, Henan province, Shaanxi, Gansu, Qinghai, Ningxia, Xinjiang Uygur Autonomous Region, housing and rural development Office, Beijing housing and Rural .Development Committee, municipal cooperated, Tianjin construction transportation authority, the Xinjiang production and construction Corps construction Bureau: <br> <br> The implementation of the State Council issued a comprehensive work programme, energy-saving emission reduction "circular (guofa [2007] .15) requirements to guide the North heating areas do the existing residential buildings heating and energy-saving alteration work, my Department has formulated "Northern heating areas existing residential buildings heating and energy-saving alteration project acceptance procedures" (at the Ministry of housing and .urban-rural website http://www.mohurd.gov.cn) are issued to you, please follow the instructions. <br> <br> <br> People's Republic of China Ministry of housing and urban-rural <br> Scrutinised .on November 12, 2009 <br> <br> Chapter 1 General provisions <br> The first implementation of the State Council issued a comprehensive work programme, energy-saving emission reduction "circular (guofa [2007] 15) work tasks, do the .North existing residential buildings heating and energy-saving alteration project approval work to develop this check methods. <br> Article 2: this method is suitable for inclusion in the national "eleventh five-year" 1.5 million square meters of existing residential buildings heating and .energy saving scheme of project acceptance. <br> Article 3, October 1, 2007 after completion of the existing residential buildings shall not be included as transformation object. <br> The four existing residential building energy-saving alteration and renovation heat metering must be .synchronized, and take the lead in implementing heating charge. No household heat metering transformation, not implementation of heating charge shall be paid by check, the Central reward Fund. <br> Chapter 2 acceptance by <br> Article 5 primarily on the basis of .acceptance of the work: <br> (A) of the Ministry of housing and urban-rural, the Ministry of Finance of the regions on promoting the North heating existing residential buildings heating and energy-saving transformation of opinion "(construction Division [2008 .] No. 95); <br> (2) the Ministry of Finance on the issuance of the notice of <Northern heating area of existing residential buildings energy-saving heating measure and reward fund management Interim Measures> (wealth-building [ .2007] 957 number); <br> (3) the Ministry of housing and urban-rural <north of existing residential building heating and energy-saving heating measure technical guidance> on issued (for trial implementation) "(construction .Division [2008] No. 126); <br> (4) the Ministry of housing and urban-rural <Northern heating measurement of existing residential building heating renovation project and check methods> on issuance of notice (City [2008] .No. 211); <br> (5) the Ministry of housing and urban-rural <civil energy efficiency evaluation identifies the technical guidance> on issued (for trial implementation) "(construction Division [2008] No. 118); .<br> (6) the technical specification of the heat metering (JGJ173-2009). <br> Chapter III acceptance conditions <br> Article 6 projects required to meet the following criteria before acceptance: <br> (A) 1 July 2009 ., recently started renovation projects, the technical solution should meet the North heating areas existing residential buildings heating and energy saving technical guidelines; July 1, 2009 will determine the transformation of technology programmes or 2009 October 1 completion of the project in the future, should meet .the technical specifications for heating. <br> (B) of the project in accordance with the approved technical programmes complete the corresponding modification of the content, quality meet the requirements of the project and construction units completed the introspection from inspection; <br> ( .3) improvement project information is complete (including the technical files, construction management information, main parts, construction materials, construction products, measurement and regulation equipment for quality certification documents, financial accounts files, etc.); <br> (4) construction .funds as planned, the proportion of counterpart funds in accordance with the regulations in place, in full and on time use and management of funds in line with the relevant provisions of the State. <br> (5) transformation projects installed household heating and temperature .regulation device, and the heating charge. <br> Chapter IV inspection content <br> 7 acceptance of content include: <br> (1) heating and energy saving renovation work is completed; <br> (2) heating and energy saving workload .assessment; <br> (3) heating and energy saving and energy-saving effects assessment; <br> (4) heating charge of implementation; <br> (5) of the funded and usage; <br> (Vi) information on .the project; <br> (7) modification of project management. <br> Chapter 5: acceptance procedures <br> 8 project implementation units complete the transformation tasks, the organization post, determines the conditions for acceptance, the seat of the city to .the project (district) level building, financial authorities submitted an application for acceptance, acceptance application report should include the following: <br> (A) renovation project basics (including project location, area, enclosure structure forms, heating system, transforming the former .energy situation, project implementation progress, etc.); <br> (2) innovation project implementation plan and techniques; <br> (3) transformation project tasks are completed and construction quality; <br> (Iv) modification of project management ( .including project management, quality management, financial management, etc.); <br> (5) heating charge of implementation; <br> (6) construction drawings and parts; <br> (7) modification of technical and economic and energy- .saving effect analysis (including project's input and output, energy efficiency, indoor thermal comfort improvement, etc.). <br> 9 City (district) level building, financial authorities received acceptance for energy efficiency, organization and evaluation bodies, relevant expert working group ., comprising acceptance on the renovation project for acceptance. Acceptance of the following steps: <br> (A) report on listening to the project to review the submitted projectApplication report of acceptance; <br> (2) check the project construction materials; < .br> (3) check the reconstruction project, work on project quality approval to check and spot checks on the reconstruction effort, energy-saving effectiveness assessment; <br> (Iv) the acceptance of the Group reviewed the project information, project acceptance. .Acceptance should have all advice signed by the members of the Working Group for acceptance; <br> (5) on the acceptance of the project, the acceptance of the Working Group should produce qualified acceptance. On failed acceptance of the project, to ask for .rectification, the grace period, conditions when organizations acceptance. <br> Article 10 the acceptance of the project, the city (district) level building, financial authorities shall submit the relevant information about the project acceptance provincial building, finance departments for review. Provincial .building, finance authorities Organization project sampling reinspection, in principle, bear the renovation of the city (district) should all sampling, sampling and testing of the project in principle should not be less than each of the city (district) of 30 per cent of .the project. <br> 11 provincial building, finance departments of the region through the acceptance of project summary, fill in the existing residential buildings heating and energy-saving alteration project acceptance record table (annex 2), reported to the Ministry of housing and .urban-rural, the Ministry of finance. <br> Article 12 of the Ministry of housing and urban-rural in conjunction with the Ministry of finance organize national energy efficiency assessment bodies throughout the project by a certain percentage of sampling, the acceptance of auditing .. <br> Chapter i. General provisions <br> Article 13 of this approach by the Ministry of housing and urban-rural construction energy conservation and science and Technology Division is responsible for the explanation. <br> Article 14: these measures as from .the date of enactment. <br>.
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment