Tuesday, December 21, 2010
Weak current College】 【medical sliding automatic door standard developed to identify important features and parameters.
<br> <br> <br> Hospital with sliding automatic doors or in the text, general medical use automatic doors sliding automatic door article hereinafter referred to as the ordinary automatic doors. Medical automatic doors and automatic gates General similarities are all straight track for .managed automatically by translational movement. Door, cradles, tension device, synchronization and synchronize these with even basic beam transmission mechanism may be generic. Are known as sliding automatic doors. While they differ mainly use sites, common use in automatic door main building, hotels ., shops, banks and other public places of entrance. The main use for medical purposes in the automatic doors of hospital buildings, inpatient Tower and hospital isolation room, the hospital surgery Department of architecture, requirements for radiation protection, sound insulation, mild seal site .entrances. The following figure is a healthcare workers access to the flowchart in clean operating room (from Beijing zhonghang century medical cleaning Engineering Co., Ltd. information). As can be seen from getting in the function room entrances must be isolated medical automatic doors .. While the ordinary automatic door is not equal. They have the essential differences, for medical automatic doors more and more special requirements. <br> There are the following: <br> A: the door, the outer surface of the stainless steel plate ., electrolytic steel plate, color steel plate, etc., with stainless steel plate for the best, but the cost is relatively high. Interlayer used foam production process, there are other radiation required door, interlayer to a certain thickness of lead plates clamp in .the middle. In addition, wall seams to have seal mosaic; <br> 2: Motor reducer, should be crafted to minimize noise in order to comply with the clean room requirements on noise; <br> 3: electronic parts must comply with the .relevant national standards for electromagnetic compatibility, to prevent interference to medical devices; <br> Four: electric control part adaptation of the voltage range is wide range; <br> 5: particular requirements for the function; <br> 1. must have auto .-start wind equipment function interface; <br> 2. must have a standby power supply access connection port; <br> 3. enhanced anti-gripping function to improve security. If you must install the safety sensors, door must have met resistance of .returns immediately after the function; <br> 4. There must be time-delayed closing function and two induction function; <br> 5. must be a non-contact-proximity sensors. If non-touch manual sensor or foot sensor. As .can be seen, because the medical automatic door above particularity, plain sliding automatic door standard far from covering the above requirement for specialized medical automatic valve setting standards is necessary; <br> Medical sliding automatic door standards to determine important parameters: <br> ⑴ ., radiation protection: χ, β, γ rays, etc.; <br> ⑵, antistatic: provides leak resistance values; <br> ⑶, heat resistance temperature: provisions; <br> ⑷, sound: sound transmission loss values stipulated; .<br> ⑸, non-control force to open the door: the small lock tension; <br> ⑹, wind pressure: maximum pressure values stipulated; <br> ⑺, static differential pressure: provides static pressure difference; <br> ⑻ ., noise: provides maximum noise values; <br> ⑼, door flatness: Max 0.5mm; <br> ⑽, sealing material: should provide the pressure values and hardness value range; <br> ⑾, anti impact; <br> ⑿ ., security: <br> ①, electrical safety, excluding 0 class equipment; <br> ②, on pedestrian safety; <br> A, require the installation of security screen; <br> B, provides medical automatic door meets resistance after a .quick return function. <br> ⒀, electromagnetic compatibility: provides power factor, the harmonic content and EMC parameters; <br> ⒁, sensors: provides short distance sensor parameters. <br> These parameters are not involved, you can reference the ordinary .automatic door standard or later supplement enriched. <br> In short, to develop a standard medical automatic doors should be in the best available medical automatic door basis increased to at least 5 years in the future to medical research and development of automatic door design guidance ., to lead the technical medical automatic doors have relatively fast leap in the development of domestic enterprises to improve the capacity of independent research and development, as to prevent low level design to eliminate low quality cheap products into the market to provide a basis for domestic or .imported medical automatic doors in a unified standard specification under more adapted to the new round of hospital isolation Chamber construction this market demand. <br> <br> <br> <br>.
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment