【 Weak current College 】 electric floor heating temperature control system installation notes
Height 1.2 meters, General and electrical lighting switches on parallel lines in the same water. Installed in the free flow of air around the wall, not subject to the other heat sources (e.g. sunlight), door and window or wall temperature, airflow.
Prior embedded electrical cassette, cassette depth appropriate 50mm above. As the wall cassettes space limit, the start up thermostat will probably meet space is small, the alignment of the difficult and pressing issues of inequality. Please carefully review the manual preparation before doing the installation. (Modified project selection out charging cable boxes in General, direct wall Ming installed).
An external sensor is installed you need holes bushing, ensure the installation, maintenance, when seated. Casing of the sealing surface should, against moisture and dirt.
Thermostat shall be installed in the bathroom, sauna, steam room or similar high-humidity, may Repulse of walls, this situation should be thermostat to lateral walls, remote control by an external sensor.
You must ensure that the heating cable for grounding and the power of the earth good connections.
Must be independent of power supply, power distribution box with overcurrent protection and leakage protection, each power supply circuit should be set with earth leakage protection device for bipolar switch.
Gas, electric power should be greater than the total power of electric heating and other electrical devices. (Otherwise, if conditions allow, the electric heating design for load distribution control).