Weak current College】 【base station, the main characteristic feature of air conditioning.


1. refrigeration and air conditioning system of base stations in two refrigeration modes: base station air conditioner refrigeration system cooling and use outdoor natural temperature refrigeration.
The former in the summer season can be active refrigeration, and guarantee that the refrigeration system energy efficiency ratio higher than 2.8.
The latter use natural conditions on the indoor temperature and humidity control, not only saving energy, and can extend the longevity of air conditioning use, reducing operational costs.
2. high reliability compressor: Coupland; control systems: domestic and international independent development engineer; host structures: domestic high-quality sheet steel
3. dual machine switch base station within two air conditioning unit that can be scheduled to switch jobs.
In one work unit fails, another unit auto switch work; or when the room temperature is too high, will start two units of work, the temperature reached the requirements range is automatically converted into a single unit of work.
4. remote communication distance central station monitoring unit at any time in the running state.
5. fault discriminant and alarm unit fails, will distinguish itself, take a failed State continued to row or downtime, measures, and alarm via remote communication.
6. heating can be configured to suit your needs, improve indoor temperature heater
7. humidification humidifier can configure as needed, improving indoor humidity
8. dehumidification units according to the room humidity Chamber set for automatic dehumidification
9. power supply line automatic recovery from power-off power, the unit can automatically restore to original state
10. all integral unit placed against Interior to ensure safety; split unit is equipped with a warning device, in the event of theft, automatically to remote central station alarm
11. temperature adjustment base station air handling units through the temperature set at a fixed range of methods to adjust the room temperature.
Can be suitable for any environment temperature conditions of the region.
As in cold areas, if the room temperature is too low, you can configure the heating device, raise the room temperature; in high heat, you can configure the dehumidification device, the lower the room temperature.
12. Prevention of condensation water freeze according to configurable condensate pipe heater to prevent condensation of water to freeze, the impact of emissions
13. unique design unit in one compact design, the products of air duct in the exhaust of the path structure design unique.
Reached to avoid air conditioning condenser of exhaust airflow short circuit problem.
At the same time provides water to ensure that when it rains there would be no indoor rain into the outside world.
14. double filtration system base station air-conditioning system in air duct design has an aluminum-made of coarse filter, it can prevent leaves, mosquito, etc. into the engine.
At run time, as long as every 2 months on a rinsing in cleaning the filter.
In the system of internal have a G4 filters, its material for non-woven fabric, filter after occurrence of dirty block is automatically issued an alert to remind the maintenance personnel to clean the filter; the filter in the system due to dirty up beep, maintain normal program work will not interfere with the normal system operation.
15. other features may need to configure additional features.